DSC Scanning Calorimeter Price Analy Differential Thermal Analysis Instrument

Max Diameter of Workpiece: <500mm

Mass Scope of Workpiece: <900kg

Type: Balancing Machine

Maxcapacity: >1000KN

Accuracy Grade: 0.5

Dsc Scanning Calorimeter Price Analy Differential Thermal Analysis Instrument Product DescriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT). Main Features:1. New designed oven structure ensures high resolution and good stability of base line;2. Air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly;3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation.Technical parameters: DSC range0~±500mW Temperature rangeroom temperature ~ 800 ºC air-cooledHeating rate1 ~ 80ºC/minTemperature resolution0.1 ºCTemperature fluctuations±0.1ºCTemperature repeatability±0.1ºCDSC noise0.01μWDSC resolution0.01μWDSC accuracy0.1μWDSC sensitivity0.1μWControl ModeRising temperature, constant temperature(full automatic programmed control)Curve scanningRising scan, *cooling scanAtmosphere controlEmbedded digital flow meter & Software controlColor24 bit 7 inches LCD touch screen displayData interfacestandard USB connectorParameter standardequipped with standard material, with a key calibration function, the usermay correct temperature and heat enthalpy Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand Packaging & ShippingOur AdvantagesFAQ

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

Gc112A Lab Gas Chromatograph Analysis Instrument

Appliance: Trace Impurity Analysis

Gaspath System: Single

Detector: Fid and Tcd

Certification: CE

Mobile Phase: Gas

GC112A Gas ChromatographGC112A gas chromatograph is suitable for trace detection of environmental protection, air and water pollution, analyzing poisons, monitoring and research, biochemistry, clinical application, pathology and virus research, food, petrochemicals, petroleum processing, oil analysis, geological , prospecting research, organic chemistry, synthesis, and quarantine, especially fit for power system, industrial and mining frontline laboratories and schools.FeaturesSynchronous bidirectional control with touch screen on the GC112A.The 7-inch color touch screen on the GC112A can display the flow rate and pressure value of theelectronic gas path.The multi core, 32-bit embedded hardware system ensures the reliable operation of the instrument.One key start up function.The extendable synchronous external trigger function can initiate GC112A and workstation throughexternal signals, such as automatic sampling device, thermal analyzer and so on.The instrument has sound system self-checking function and malfunction automatic identificationfunction.The instrument has 8 external event interface with extendable functions, which can work with avariety of functional control valve, performing according to the set timing.The memory function can store 20-sample test modes.RS232 communication port and LAN port.N2000 chromatography workstation.SpecificationsOven: Inside capacity: 22LTemperature range: room temperature up 5ºC-400ºC Temperature accuracy: ±0.1 ºCTemperature programming: 9 step Program total time: 9999.9 min Max heating rate: 0.1-60ºC/minMax cooling rate: <=10mins(250ºC-50ºC)Sample Injector: Temperature range: room temperature up7ºC~ 420 ºCTemp control type: independentCarrier gas flow control type: constant pressure Max quantity: 3PcsType: Packed column or split Split ratio: displayPre column pressure range: 0-400kpa Pre column pressure accuracy: 0.1kpa Flow setting range: H2 0-200ml/minN2 0-150ml/minDetector: FID or TCDTemperature Range: room temperature up 7ºC~ 420 ºCMax installation Qty.: 2 Ignition model: automaticHydrogen Flame lonization Detector (FID): Logarithmic amplifierHigh Voltage Switch Control Baseline signal displayDetection limit: <=3x10 -12 g/s( sample: n-hexadecane)Overall Dimension & Weight: Power: 220V±22V, 50Hz±0.5Hz, 3000WPackage size: 735mmx725mmx835mm G.W.: 82kgN.W.: 70kgBaseline noise: <=5x10-14A Baseline draft: <=6x10 -13 A Dynamic range: 107RSD: <=3%Thermal Conductivity Detector (TCD): Sencitivity:8000mV.ml/mg (sample:n-hexadecane)Baseline noise: <=0.05mV Baseline draft: <=0.15mV/ 30min Dynamic range: 105

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

DSC Thermogravimetry Tga Differential Scanning Calorimeter Analysis Analyzer Instrument

Max Diameter of Workpiece: <500mm

Mass Scope of Workpiece: <900kg

Type: Balancing Machine

Maxcapacity: >1000KN

Accuracy Grade: 0.5

Differential Scanning Calorimeter Price Calorimetry Thermal Analysis Analyzer DscProduct Description Thermo gravimetric analyzer (TGA) is in TG, temperature, the temperature or cooling process, observe the quality with temperature or the change of time, the purpose is to study material thermal stability and components. Widely used in plastic, rubber, coating, drugs, catalyst, inorganic materials, metal materials and composites fields of research and development, optimizing process and quality controlMeasurement and research material following characteristics:Thermal stability, decomposing process, adsorption and desorption, oxidation and reduction, ingredients quantitative analysis, additives and filler influence, moisture and volatiles, reaction kinetics. Technical parameters: Temperature range: Room temperature ~1350ºCTemperature fluctuation: ±0.1ºC Heating rate:1 ~ 80 ºC / minTemperature control mode: Rising temperature, Cooling temperature, Constant temperatureThe cooling time: 15min (1000ºC ~ 100ºC)Balance measuring scope: 1mg~2g (Can be extended to 30g)Resolution: 0.1 u gConstant temperature and time: 0 ~ 300min (set arbitrarily)Display:Chinese characters liquid crystal display (LCD)Atmosphere: inert, oxidizing, reducible, static and dynamicAtmosphere device: Built-in gas flow meter, including switch two way gas and control flow volumeSoftware:Intelligent software can record TG curves automatically, Processing data and print experimental statementsData interface:RSS - 232 interface, special software (irregularly free upgrades) Power: AC220V 50HzPackaging & ShippingOur AdvantagesFAQ

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China