After-sales Service: Free Spare Parts; Online Support
Warranty: 2 Years
Kind: Digital Oscilloscope
Channel Number: 2
Structure: Desktop
Bioevopeak 7 inches color LCD Display 2 Channels OscilloscopeFeatures1. Channels: 22. Bandwidth: 25MHz, 100MHz3. Sample Rate: 100MS/s, 1GS/s4. Display: 7″ color LCD, 800 x 480 pixels.SpecificationTechnical DataDSO-1022DSO-1102Channels22Bandwidth25MHz100MHzSample Rate100MS/s1GS/sDisplay7″ color LCD, 800 x 480 pixelsHorizontalScale5ns/div - 1000s/div2ns/div - 1000s/divRise Time17.5ns3.5nsInput Impedance1MΩ ± 2%, in parallel with 20pF±5pFChannel Isolation50Hz : 100 : 1, 10MHz : 40 : 1Max Input Voltage400V (PK - PK) (DC+AC,PK - PK)DC Gain Accuracy±3%Record Length10KDC Accuracy(average)≥16:±(3% reading + 0.05 div) for ΔVProbe Attenuation Factor1X, 10X, 100X, 1000XLF Respond (AC, -3dB)10Hz (at input, AC coupling,-3dB)Sample Rate±100ppmRelay Time AccuracyInterpolationsin (x) / xInterval (ΔT) AccuracySingle : ±(1 interval time + 100ppm x reading + 0.6ns)(full bandwidth)Average>16: ±(1 interval time + 100ppm x reading+ 0.4ns)Input CouplingDC, AC , and GNDVertical Resolution(A/D)8 bits (2 channels simultaneously)Vertical Sensitivity5mV/div - 5V/div (at input)Trigger TypeEdge, VideoTrigger ModeAuto, Normal, and SingleTrigger Level±5 divisionsfrom screen centerLine / Field Frequency (video)NTSC, PAL and SECAM standardCursor MeasurementΔV, and ΔT betweencursorsAutomatic MeasurementVpp, Vavg, RMS, Frequency, Period, Vmax, Vmin, Vtop, Vbase,Width, Overshoot, Pre-shoot, Rise time, Fall time, +Width, -Width,+Duty,-Duty, Delay A->B (up) , Delay A->B (down) , area, cycle areaWaveform Math+, -, x, ÷, invert, FFTWaveform Storage16 waveformsLissajous Figure BandwidthFull bandwidthPhase Difference±3 degreesCommunication InterfaceUSB host, USB deviceFrequency CounteravailablePower Supply100V - 240V AC, 50/60Hz, CAT IIPower Consumption<15WFuse2A, T class, 250VDimension (W x H x D)301 x 152 x 70 mmWeight1.10 kgPackaging & ShippingCertificationsAbout usFAQQ: How about quality of the goods?A:l All the running products comply with CE standards.l Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.l Well-known third-party testing service available, such as SGS, BV, and TUV, etc. Q: What are your pre- and after-sales services?A:l Timely reply to pre-sales enquiriesl Real-time update of manufacturing and shipment statusl Contracted third-party maintenance company in over 60 countriesAssured availability of parts supply for 10 years at least Q: Is OEM service available.A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization. Q: How long is the lead time:A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.
After-sales Service: Free Spare Parts; Online Support
Warranty: 2 Years
Kind: Digital Oscilloscope
Channel Number: 2
Structure: Desktop
Bioevopeak 7 inches color LCD Display 2 Channels OscilloscopeFeatures1. Channels: 22. Bandwidth: 25MHz, 100MHz3. Sample Rate: 100MS/s, 1GS/s4. Display: 7″ color LCD, 800 x 480 pixels.SpecificationTechnical DataDSO-1022DSO-1102Channels22Bandwidth25MHz100MHzSample Rate100MS/s1GS/sDisplay7″ color LCD, 800 x 480 pixelsHorizontalScale5ns/div - 1000s/div2ns/div - 1000s/divRise Time17.5ns3.5nsInput Impedance1MΩ ± 2%, in parallel with 20pF±5pFChannel Isolation50Hz : 100 : 1, 10MHz : 40 : 1Max Input Voltage400V (PK - PK) (DC+AC,PK - PK)DC Gain Accuracy±3%Record Length10KDC Accuracy(average)≥16:±(3% reading + 0.05 div) for ΔVProbe Attenuation Factor1X, 10X, 100X, 1000XLF Respond (AC, -3dB)10Hz (at input, AC coupling,-3dB)Sample Rate±100ppmRelay Time AccuracyInterpolationsin (x) / xInterval (ΔT) AccuracySingle : ±(1 interval time + 100ppm x reading + 0.6ns)(full bandwidth)Average>16: ±(1 interval time + 100ppm x reading+ 0.4ns)Input CouplingDC, AC , and GNDVertical Resolution(A/D)8 bits (2 channels simultaneously)Vertical Sensitivity5mV/div - 5V/div (at input)Trigger TypeEdge, VideoTrigger ModeAuto, Normal, and SingleTrigger Level±5 divisionsfrom screen centerLine / Field Frequency (video)NTSC, PAL and SECAM standardCursor MeasurementΔV, and ΔT betweencursorsAutomatic MeasurementVpp, Vavg, RMS, Frequency, Period, Vmax, Vmin, Vtop, Vbase,Width, Overshoot, Pre-shoot, Rise time, Fall time, +Width, -Width,+Duty,-Duty, Delay A->B (up) , Delay A->B (down) , area, cycle areaWaveform Math+, -, x, ÷, invert, FFTWaveform Storage16 waveformsLissajous Figure BandwidthFull bandwidthPhase Difference±3 degreesCommunication InterfaceUSB host, USB deviceFrequency CounteravailablePower Supply100V - 240V AC, 50/60Hz, CAT IIPower Consumption<15WFuse2A, T class, 250VDimension (W x H x D)301 x 152 x 70 mmWeight1.10 kgPackaging & ShippingCertificationsAbout usFAQQ: How about quality of the goods?A:l All the running products comply with CE standards.l Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.l Well-known third-party testing service available, such as SGS, BV, and TUV, etc. Q: What are your pre- and after-sales services?A:l Timely reply to pre-sales enquiriesl Real-time update of manufacturing and shipment statusl Contracted third-party maintenance company in over 60 countriesAssured availability of parts supply for 10 years at least Q: Is OEM service available.A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization. Q: How long is the lead time:A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.
Kind: Digital Oscilloscope
Channel Number: 1
Structure: Desktop
Application: Laboratory Oscilloscope
Sampling Mode: Real-time Sampling
Product Description:1. Approval quality.2. In Neutro-packing3. Certification: ISO Single Channel OscilloscopeModel No.J2459Width of band(-3dB)DC(AC 10Hz)~2MHzSensitivity50mV/DIV±10%Input impedance1mΩ±5% 40pF±5pFPackaging & Shipping: Packaging Size (L*W*D) CM Gross Weight KG Pack Detail:1. The normal package is hard carton box 2. Accept wooden box packing in charge.3. Pack it according to customers special request.Our Service:Pre-Sales Service After-Sales Service* Reply in 24 hours* Training how to instal the machine,* Inquiry and consulting support. training how to use the machine * Sample testing support. * Engineers available to service machinery* View our Company. overseas. Guangzhou Address:GZ KWOK LAM Medical Instrument & Equipments City A3-157.No.600, Huawan Road, Fangcun, Liwan Area, Guangzhou.FAQ:1. Q: How long is the warranty time? A: 12 Months2. Q: What is the payment method? A: Credit card, Westunion, TT, Moneygram, Paypal, L/C, D/A, D/P etc. 3. Q: When do you delivery? A: Usually in 7-30 days.4. Q: Could you offer intallation or tranning oversea? A: Yes, we offer the service for complex machine in charge.5. Q: It is my 1st time purchase products oversea, how to promise its safe? A: You can place orders on Alibaba, it takes guarranty for you.6. Q: Can I order a sample? A: Sure, delivery sample by global express in charge.Related ProductsDownload Catalogue:
Kind: Digital Oscilloscope
Channel Number: 1
Structure: Desktop
Application: Laboratory Oscilloscope
Sampling Mode: Real-time Sampling
Product Description:1. Approval quality.2. In Neutro-packing3. Certification: ISO Single Channel OscilloscopeModel No.J2459Width of band(-3dB)DC(AC 10Hz)~2MHzSensitivity50mV/DIV±10%Input impedance1mΩ±5% 40pF±5pFPackaging & Shipping: Packaging Size (L*W*D) CM Gross Weight KG Pack Detail:1. The normal package is hard carton box 2. Accept wooden box packing in charge.3. Pack it according to customers special request.Our Service:Pre-Sales Service After-Sales Service* Reply in 24 hours* Training how to instal the machine,* Inquiry and consulting support. training how to use the machine * Sample testing support. * Engineers available to service machinery* View our Company. overseas. Guangzhou Address:GZ KWOK LAM Medical Instrument & Equipments City A3-157.No.600, Huawan Road, Fangcun, Liwan Area, Guangzhou.FAQ:1. Q: How long is the warranty time? A: 12 Months2. Q: What is the payment method? A: Credit card, Westunion, TT, Moneygram, Paypal, L/C, D/A, D/P etc. 3. Q: When do you delivery? A: Usually in 7-30 days.4. Q: Could you offer intallation or tranning oversea? A: Yes, we offer the service for complex machine in charge.5. Q: It is my 1st time purchase products oversea, how to promise its safe? A: You can place orders on Alibaba, it takes guarranty for you.6. Q: Can I order a sample? A: Sure, delivery sample by global express in charge.Related ProductsDownload Catalogue:
Kind: Digital Oscilloscope
Channel Number: 1
Structure: Desktop
Application: Laboratory Oscilloscope
Sampling Mode: Real-time Sampling
Product Description:1. Approval quality.2. In Neutro-packing3. Certification: ISO Single Channel OscilloscopeModel No.J2459Width of band(-3dB)DC(AC 10Hz)~2MHzSensitivity50mV/DIV±10%Input impedance1mΩ±5% 40pF±5pFPackaging & Shipping: Packaging Size (L*W*D) CM Gross Weight KG Pack Detail:1. The normal package is hard carton box 2. Accept wooden box packing in charge.3. Pack it according to customers special request.Our Service:Pre-Sales Service After-Sales Service* Reply in 24 hours* Training how to instal the machine,* Inquiry and consulting support. training how to use the machine * Sample testing support. * Engineers available to service machinery* View our Company. overseas. Guangzhou Address:GZ KWOK LAM Medical Instrument & Equipments City A3-157.No.600, Huawan Road, Fangcun, Liwan Area, Guangzhou.FAQ:1. Q: How long is the warranty time? A: 12 Months2. Q: What is the payment method? A: Credit card, Westunion, TT, Moneygram, Paypal, L/C, D/A, D/P etc. 3. Q: When do you delivery? A: Usually in 7-30 days.4. Q: Could you offer intallation or tranning oversea? A: Yes, we offer the service for complex machine in charge.5. Q: It is my 1st time purchase products oversea, how to promise its safe? A: You can place orders on Alibaba, it takes guarranty for you.6. Q: Can I order a sample? A: Sure, delivery sample by global express in charge.Related ProductsDownload Catalogue:
After-sales Service: Yes
Warranty: 1 Year
Kind: Digital Oscilloscope
Channel Number: 2
Structure: Desktop
Hantek 2D82 Auto Car Handheld Oscilloscope 4 in 1 Dual Channels Portable Digital Wave Generator Multimeter Automotive DiagnosisDSO5000P SeriesBandwidth:70-200MHz;1GSa/s Real Time Sample Rate;Record length up to 40K; Multiple automatic measurements; Large (7.0-inch) colordisplay, WVGA(800x480);Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.Feature:* 200/100/70MHz bandwidths* 1GSa/s Real Time sample rate* Large (7.0-inch) color display, WVGA(800x480)* Record length up to 40K* Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.* USB host and device connectivity, standard* Multiple automatic measurements* Four math functions, including FFTs standard* Provides software for PC real-time analysis ModelDSO5202PDSO5102PDSO5072PAcquisitionSample RateReal-Time Sample: 1GS/sEquivalent Sample: 25GS/sAcquisition Modes NormalNormal data onlyPeak-DetectHigh-frequency and randon glith captureAverageWavefom Average, selectable 4,8,16,32,64,128InputsInputs CouplingAC, DC, GNDInpits Impendance1MΩ±2% II20pF±3pFProbe Attenuation1X, 10XSupported Probe Attenuation Factor1X, 10X, 100X, 1000XMaximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×);Installation Category II: derate at 20dB/decade above 100kHz to 13V peak-AC at 3MHz* and above.For non-sinusoidal waveforms, peak-value must be less than 450V.Excursion above 300V should be of less than 100ms duration.RMS signal level including all DC components removed through AC coupling must be limited to 300V.If these values are exceeded, damage to the oscilloscope may occur.HorizontalSample Rate Range500MS/s--1GS/sWaveform Interpolation(sin x)/xRecord Length40 KSEC/DIV Range4ns/div to 40s/div4ns/div to 40s/divSample Rate and±50ppm(at over any ≥1ms time interval)Delay Time AccuracyPosition Range2ns/div to 10ns/div;20ns/div to 80us/div; (-8div x s/div) to 40ms;(-4div x s/div) to 20ms;200us/div to 40s/div; (-8div x s/div) to 400sDelta-Time Measurement AccuracySingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);(Full Bandwidth)>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200VerticalVertical Resolution8-bit resolution, all channel sampled simultaneouslyPosition Range2mV/div to 200mV/div, ±2V200mV/div to 5V/div, ±50VBandwidth100MHz100MHz70MHzRise Time at BNC( typical)3.5ns3.5ns5nsAnalog Bandwidth in Normal and2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2VAverage modes at BNC or with probe, DC Coupled500mV/div to 2V/div, ±40V; 5V/div, ±50VMath+, -, *, /, FFTFFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;1024 sample pointBandwidth Limit20MHzLow Frequency Response (-3db)≤10Hz at BNCDC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy,When vertical displacement is-zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;Average Acquisition ModeWhen vertical displacement is not-zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability,Delta-volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditionsAverage Acquisition ModeTrigger SystemTrigger TypesEdge,Video, Pulse, Slope, Over time, AlternativeTrigger SourceCH1, CH2, EXT, EXT/5, AC LineTrigger ModesAuto, Normal, SingleCoupling TypeDC, AC, Noise Reject, HF Reject, LF RejectTrigger SensitivityDC(CH1,CH2):(Edge-Trigger Type)1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHzTrigger Level RangeCH1/CH2: ±8 divisions from center of screen;EXT: ±1.2V;EXT/5:±6VTrigger Level Accuracy( typical)AccuracyCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;is for signals having rise and fall times ≥20nsEXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);Set Level to 50%(typical)Operates with input signals ≥50HzVideo Trigger Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;EXT: 400mV;EXT/5: 2VSignal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any lineHoldoff Range100ns ~ 10sPulse Width Trigger Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulsePulse Width Trigger PointEqual: The oscilloscope triggers when the trailing-edge of the pulse the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing-edge.Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing-edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified asthe Pulse WidthPulse Width Range20ns ~ 10sSlope Trigger Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slopeSlope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.Time Range20ns ~ 10sOvertime Trigger Over Time ModeRising-edge or Falling-edgeTime Range20ns ~ 10sAlternative Trigger Trigger on CH1Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger on CH2Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger Frequency CounterReadout Resolution6 digitsAccuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)Frequency RangeAC coupled, from 4Hz minimum to rated bandwidthSignal SourcePulse Width or Edge Trigger modes: all available trigger sourcesThe Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pausesdue to changes in the run status, or acquisition of a single shot event has completed.Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify astriggerable events,such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.Video Trigger mode: The Frequency Counter does not work.MeasureCursor MeasurementVoltage difference between cursors: ΔVTime difference between cursors: ΔTReciprocal of ΔT in Hertz (1/ΔT)Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise,Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,FRF, FFR, LRR, LRF, LFR, LFFDisplayDisplay Type7 inch 64K color TFT (diagonal liquid crystal)Display Resolution800 horizontal by 480 vertical pixelsDisplay ContrastAdjustable (16 gears) with the progress barProbe Compensator OutputOutput Voltage( typical)About 5Vpp into ≥1MΩ loadFrequency(typical)1kHzPower SupplySupply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CATII120-240VACRMS(±10%), 45Hz to 66Hz, CATIIPower Consumption<30WFuse2A, T rating, 250VEnvironmentalTemperatureOperating: 32F to 122F (0C to 50C);Nonoperating: -40F to 159.8F (-40C to +71C)Cooling MethodConvectionHumidity+104F or below (+40C or below): ≤90% relative humidity;106F to 122F (+41C to 50C): ≤60% relative humidityAltitudeOperating: Below 3,000m (10,000 feet);Nonoperaring: Below 15,000m(50,000 feet)MechanicalSizeLength 385mm, Width 200mm, Height 245mm FAQ1. Are you a manufacturer or a trader?Yes, we are both. 2. What products do you have?We are focus on instruments and meters. Such as Mechanical / Optical /Power/ SafetyEnvironmental testing equipments andsome hardware tools amd eletronic components.More infomation about business, please contact us we can send you catalog for reference.3. Can i get a sample first?Yes, we are pleased to send you sample to test the quality and market.4. Can you do OEM for us?Yes, OEM are welcome for us. Customers' brand, logo, label can be customized for the produets andcarton package, but based on a certain quantity.5. What are your strengths?We have a complete range of products covering low, medium and high-end markets in good price in Instruments field.Fast Delivery, factory high quality and professional engineers to solve your problems.
After-sales Service: Yes
Warranty: 1 Year
Kind: Digital Oscilloscope
Channel Number: 2
Structure: Desktop
Hantek 2D82 Auto Car Handheld Oscilloscope 4 in 1 Dual Channels Portable Digital Wave Generator Multimeter Automotive DiagnosisDSO5000P SeriesBandwidth:70-200MHz;1GSa/s Real Time Sample Rate;Record length up to 40K; Multiple automatic measurements; Large (7.0-inch) colordisplay, WVGA(800x480);Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.Feature:* 200/100/70MHz bandwidths* 1GSa/s Real Time sample rate* Large (7.0-inch) color display, WVGA(800x480)* Record length up to 40K* Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.* USB host and device connectivity, standard* Multiple automatic measurements* Four math functions, including FFTs standard* Provides software for PC real-time analysis ModelDSO5202PDSO5102PDSO5072PAcquisitionSample RateReal-Time Sample: 1GS/sEquivalent Sample: 25GS/sAcquisition Modes NormalNormal data onlyPeak-DetectHigh-frequency and randon glith captureAverageWavefom Average, selectable 4,8,16,32,64,128InputsInputs CouplingAC, DC, GNDInpits Impendance1MΩ±2% II20pF±3pFProbe Attenuation1X, 10XSupported Probe Attenuation Factor1X, 10X, 100X, 1000XMaximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×);Installation Category II: derate at 20dB/decade above 100kHz to 13V peak-AC at 3MHz* and above.For non-sinusoidal waveforms, peak-value must be less than 450V.Excursion above 300V should be of less than 100ms duration.RMS signal level including all DC components removed through AC coupling must be limited to 300V.If these values are exceeded, damage to the oscilloscope may occur.HorizontalSample Rate Range500MS/s--1GS/sWaveform Interpolation(sin x)/xRecord Length40 KSEC/DIV Range4ns/div to 40s/div4ns/div to 40s/divSample Rate and±50ppm(at over any ≥1ms time interval)Delay Time AccuracyPosition Range2ns/div to 10ns/div;20ns/div to 80us/div; (-8div x s/div) to 40ms;(-4div x s/div) to 20ms;200us/div to 40s/div; (-8div x s/div) to 400sDelta-Time Measurement AccuracySingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);(Full Bandwidth)>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200VerticalVertical Resolution8-bit resolution, all channel sampled simultaneouslyPosition Range2mV/div to 200mV/div, ±2V200mV/div to 5V/div, ±50VBandwidth100MHz100MHz70MHzRise Time at BNC( typical)3.5ns3.5ns5nsAnalog Bandwidth in Normal and2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2VAverage modes at BNC or with probe, DC Coupled500mV/div to 2V/div, ±40V; 5V/div, ±50VMath+, -, *, /, FFTFFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;1024 sample pointBandwidth Limit20MHzLow Frequency Response (-3db)≤10Hz at BNCDC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy,When vertical displacement is-zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;Average Acquisition ModeWhen vertical displacement is not-zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability,Delta-volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditionsAverage Acquisition ModeTrigger SystemTrigger TypesEdge,Video, Pulse, Slope, Over time, AlternativeTrigger SourceCH1, CH2, EXT, EXT/5, AC LineTrigger ModesAuto, Normal, SingleCoupling TypeDC, AC, Noise Reject, HF Reject, LF RejectTrigger SensitivityDC(CH1,CH2):(Edge-Trigger Type)1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHzTrigger Level RangeCH1/CH2: ±8 divisions from center of screen;EXT: ±1.2V;EXT/5:±6VTrigger Level Accuracy( typical)AccuracyCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;is for signals having rise and fall times ≥20nsEXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);Set Level to 50%(typical)Operates with input signals ≥50HzVideo Trigger Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;EXT: 400mV;EXT/5: 2VSignal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any lineHoldoff Range100ns ~ 10sPulse Width Trigger Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulsePulse Width Trigger PointEqual: The oscilloscope triggers when the trailing-edge of the pulse the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing-edge.Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing-edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified asthe Pulse WidthPulse Width Range20ns ~ 10sSlope Trigger Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slopeSlope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.Time Range20ns ~ 10sOvertime Trigger Over Time ModeRising-edge or Falling-edgeTime Range20ns ~ 10sAlternative Trigger Trigger on CH1Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger on CH2Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger Frequency CounterReadout Resolution6 digitsAccuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)Frequency RangeAC coupled, from 4Hz minimum to rated bandwidthSignal SourcePulse Width or Edge Trigger modes: all available trigger sourcesThe Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pausesdue to changes in the run status, or acquisition of a single shot event has completed.Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify astriggerable events,such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.Video Trigger mode: The Frequency Counter does not work.MeasureCursor MeasurementVoltage difference between cursors: ΔVTime difference between cursors: ΔTReciprocal of ΔT in Hertz (1/ΔT)Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise,Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,FRF, FFR, LRR, LRF, LFR, LFFDisplayDisplay Type7 inch 64K color TFT (diagonal liquid crystal)Display Resolution800 horizontal by 480 vertical pixelsDisplay ContrastAdjustable (16 gears) with the progress barProbe Compensator OutputOutput Voltage( typical)About 5Vpp into ≥1MΩ loadFrequency(typical)1kHzPower SupplySupply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CATII120-240VACRMS(±10%), 45Hz to 66Hz, CATIIPower Consumption<30WFuse2A, T rating, 250VEnvironmentalTemperatureOperating: 32F to 122F (0C to 50C);Nonoperating: -40F to 159.8F (-40C to +71C)Cooling MethodConvectionHumidity+104F or below (+40C or below): ≤90% relative humidity;106F to 122F (+41C to 50C): ≤60% relative humidityAltitudeOperating: Below 3,000m (10,000 feet);Nonoperaring: Below 15,000m(50,000 feet)MechanicalSizeLength 385mm, Width 200mm, Height 245mm FAQ1. Are you a manufacturer or a trader?Yes, we are both. 2. What products do you have?We are focus on instruments and meters. Such as Mechanical / Optical /Power/ SafetyEnvironmental testing equipments andsome hardware tools amd eletronic components.More infomation about business, please contact us we can send you catalog for reference.3. Can i get a sample first?Yes, we are pleased to send you sample to test the quality and market.4. Can you do OEM for us?Yes, OEM are welcome for us. Customers' brand, logo, label can be customized for the produets andcarton package, but based on a certain quantity.5. What are your strengths?We have a complete range of products covering low, medium and high-end markets in good price in Instruments field.Fast Delivery, factory high quality and professional engineers to solve your problems.
After-sales Service: Yes
Warranty: 1 Year
Kind: Digital Oscilloscope
Channel Number: 2
Structure: Desktop
Hantek 2D82 Auto Car Handheld Oscilloscope 4 in 1 Dual Channels Portable Digital Wave Generator Multimeter Automotive DiagnosisDSO5000P SeriesBandwidth:70-200MHz;1GSa/s Real Time Sample Rate;Record length up to 40K; Multiple automatic measurements; Large (7.0-inch) colordisplay, WVGA(800x480);Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.Feature:* 200/100/70MHz bandwidths* 1GSa/s Real Time sample rate* Large (7.0-inch) color display, WVGA(800x480)* Record length up to 40K* Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.* USB host and device connectivity, standard* Multiple automatic measurements* Four math functions, including FFTs standard* Provides software for PC real-time analysis ModelDSO5202PDSO5102PDSO5072PAcquisitionSample RateReal-Time Sample: 1GS/sEquivalent Sample: 25GS/sAcquisition Modes NormalNormal data onlyPeak-DetectHigh-frequency and randon glith captureAverageWavefom Average, selectable 4,8,16,32,64,128InputsInputs CouplingAC, DC, GNDInpits Impendance1MΩ±2% II20pF±3pFProbe Attenuation1X, 10XSupported Probe Attenuation Factor1X, 10X, 100X, 1000XMaximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×);Installation Category II: derate at 20dB/decade above 100kHz to 13V peak-AC at 3MHz* and above.For non-sinusoidal waveforms, peak-value must be less than 450V.Excursion above 300V should be of less than 100ms duration.RMS signal level including all DC components removed through AC coupling must be limited to 300V.If these values are exceeded, damage to the oscilloscope may occur.HorizontalSample Rate Range500MS/s--1GS/sWaveform Interpolation(sin x)/xRecord Length40 KSEC/DIV Range4ns/div to 40s/div4ns/div to 40s/divSample Rate and±50ppm(at over any ≥1ms time interval)Delay Time AccuracyPosition Range2ns/div to 10ns/div;20ns/div to 80us/div; (-8div x s/div) to 40ms;(-4div x s/div) to 20ms;200us/div to 40s/div; (-8div x s/div) to 400sDelta-Time Measurement AccuracySingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);(Full Bandwidth)>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200VerticalVertical Resolution8-bit resolution, all channel sampled simultaneouslyPosition Range2mV/div to 200mV/div, ±2V200mV/div to 5V/div, ±50VBandwidth100MHz100MHz70MHzRise Time at BNC( typical)3.5ns3.5ns5nsAnalog Bandwidth in Normal and2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2VAverage modes at BNC or with probe, DC Coupled500mV/div to 2V/div, ±40V; 5V/div, ±50VMath+, -, *, /, FFTFFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;1024 sample pointBandwidth Limit20MHzLow Frequency Response (-3db)≤10Hz at BNCDC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy,When vertical displacement is-zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;Average Acquisition ModeWhen vertical displacement is not-zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability,Delta-volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditionsAverage Acquisition ModeTrigger SystemTrigger TypesEdge,Video, Pulse, Slope, Over time, AlternativeTrigger SourceCH1, CH2, EXT, EXT/5, AC LineTrigger ModesAuto, Normal, SingleCoupling TypeDC, AC, Noise Reject, HF Reject, LF RejectTrigger SensitivityDC(CH1,CH2):(Edge-Trigger Type)1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHzTrigger Level RangeCH1/CH2: ±8 divisions from center of screen;EXT: ±1.2V;EXT/5:±6VTrigger Level Accuracy( typical)AccuracyCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;is for signals having rise and fall times ≥20nsEXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);Set Level to 50%(typical)Operates with input signals ≥50HzVideo Trigger Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;EXT: 400mV;EXT/5: 2VSignal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any lineHoldoff Range100ns ~ 10sPulse Width Trigger Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulsePulse Width Trigger PointEqual: The oscilloscope triggers when the trailing-edge of the pulse the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing-edge.Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing-edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified asthe Pulse WidthPulse Width Range20ns ~ 10sSlope Trigger Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slopeSlope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.Time Range20ns ~ 10sOvertime Trigger Over Time ModeRising-edge or Falling-edgeTime Range20ns ~ 10sAlternative Trigger Trigger on CH1Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger on CH2Internal Trigger:-Edge, Pulse Width, Video, SlopeTrigger Frequency CounterReadout Resolution6 digitsAccuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)Frequency RangeAC coupled, from 4Hz minimum to rated bandwidthSignal SourcePulse Width or Edge Trigger modes: all available trigger sourcesThe Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pausesdue to changes in the run status, or acquisition of a single shot event has completed.Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify astriggerable events,such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.Video Trigger mode: The Frequency Counter does not work.MeasureCursor MeasurementVoltage difference between cursors: ΔVTime difference between cursors: ΔTReciprocal of ΔT in Hertz (1/ΔT)Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise,Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,FRF, FFR, LRR, LRF, LFR, LFFDisplayDisplay Type7 inch 64K color TFT (diagonal liquid crystal)Display Resolution800 horizontal by 480 vertical pixelsDisplay ContrastAdjustable (16 gears) with the progress barProbe Compensator OutputOutput Voltage( typical)About 5Vpp into ≥1MΩ loadFrequency(typical)1kHzPower SupplySupply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CATII120-240VACRMS(±10%), 45Hz to 66Hz, CATIIPower Consumption<30WFuse2A, T rating, 250VEnvironmentalTemperatureOperating: 32F to 122F (0C to 50C);Nonoperating: -40F to 159.8F (-40C to +71C)Cooling MethodConvectionHumidity+104F or below (+40C or below): ≤90% relative humidity;106F to 122F (+41C to 50C): ≤60% relative humidityAltitudeOperating: Below 3,000m (10,000 feet);Nonoperaring: Below 15,000m(50,000 feet)MechanicalSizeLength 385mm, Width 200mm, Height 245mm FAQ1. Are you a manufacturer or a trader?Yes, we are both. 2. What products do you have?We are focus on instruments and meters. Such as Mechanical / Optical /Power/ SafetyEnvironmental testing equipments andsome hardware tools amd eletronic components.More infomation about business, please contact us we can send you catalog for reference.3. Can i get a sample first?Yes, we are pleased to send you sample to test the quality and market.4. Can you do OEM for us?Yes, OEM are welcome for us. Customers' brand, logo, label can be customized for the produets andcarton package, but based on a certain quantity.5. What are your strengths?We have a complete range of products covering low, medium and high-end markets in good price in Instruments field.Fast Delivery, factory high quality and professional engineers to solve your problems.