After-sales Service: Long-Term
Application: Laboratory Apparatus
Warranty: 1 Years
Detection Method: Spectrophotometer
Advantage: Factory Directly Sale
Laser Particle Size Analyzer for powder size testing Product DescriptionIntroduce:LS-909 is a new cost-effective laser particle size analyzer designed and manufactured by Omec relying on powerful R&D managerial experience from Spectris and combining the market application features of LS-POP(6)- the star product and sales champion at present after Omec joining in UK Spectris plc. It will bring a feeling of freshness to powder industry with higher testing performance.Applications:Measure the particle size distribution of powder or latex.Principle: Light is an electromagnetic wave. When light meets with particles on it way of traveling, the interaction between light and particles will result in deviations of part of the light, which is called light scattering. The bigger the scattering angle is, the particle size will be smaller, the smaller the scattering angle is, the particle size will be bigger. The particle analyzer instruments will analysis the particle distribution according to this physical character of the light wave.Detailed PhotosProduct ParametersSpecifications:Theory Mie scatteringMeasuring Range0.02-2100μmSample Feeding wet dispersionRepeatability <1% (standard sample D50)Scan frequency 1 kHzMeasurement Duration 1-2 minutesNumber of Detectors 49Light Source He-Ne laser, 2.0 mW, 0.6328 μmTemperature 5-35ºCHumidity<85%Report Items Particle size distribution table & graph, Average diameter, Median diameter, SSA, etc.Dimension(L X W X H)838 X 265 X 295mm(mainframe)Technical features Reliable optical platform1. Use horizontal straight light path layout, no reflecting prism, light path is stable and reliable.2. Good designability for base, good consistency of light path.3. GB/T4857.18 drop test has been passed.4. Anti-moist ability of laser power module and the stability of electric are better.5. Modular construction design, maintenance is more convenient.6. The testing performance for small particles is improved.7. The all-in-one housing design, it's dust-protected and water-proof.Schematic diagram of optical path1. Totally enclosed design of light path system, dust pollution and external light pollution can be prevented.2. Light path adopts lens back Fourier transform structure.3. Optical source adopts He-Ne laser emitter which owns better monochromaticity, high coherence, small divergence angle and good stability compared to other laser emitters,we also adopt the patent design of integrated laser emitter(patent no.: 00228952.0) which reduces heat distortion of laser tube and external mechanical vibration.4. For laser emitter, except for traditional detection of output power value, we add the stability test of output power. 5. Smoothing processing technology is used to reduce the impact of power fluctuation to measurement.6. Constant current limit and filling process of laser tube are used to reduce the flash frequency to the minimum.7. Backward detector is added, the lower limit of measurement is extended to 0.1micron.8. Spatial filter is fixed by powerful permanent magnet, the pinhole is not easy to shift under the disturbance of external force, so the stability of the optical path has been greatly improved. Besides, the new designed spatial filter eliminates the laser diffraction ring more effectively, the light background of the instrument is lower, optical energy data is more accurate, it is helpful to improve the testing capability for large particles.9. Detector array adopts unique scattered light detection around a sphere surface (DAS) (patent no.: 95223756.3), the large angle detectors are placed in a spherical surface to get accurate focus of the large angle scattered light.Advanced data collection and processing technology1.New designed data collecting board uses 32 bit CPU from famous chip design company-ARM,the CPU has the advantages of high-effective signal processing capacity and low power consumption.2.Using 8-channel simultaneous sampling to sample 16 bit ADC, the sampling frequency of frame data can reach 1 kHz.3.Using 64-channel simultaneous sampling technology and sample & hold switch with ultralow leakage current, the full scale accuracy can reach 0.15%.4.Easy to update the firmware and layout data, more convenient for maintenance and operation5.Offset function of electric background, it can help to get more accurate optical energy data.Related ProductsClick the photo to get more details: Packaging & ShippingCompany ProfileFAQFAQ:Q1: Why Choose NANBEI ?(1).Professional manufacturer with more than 13 years experience(2).Exported to more than 97% Countries(3).Turnkey Solution is no problemQ2:OEM,ODM acceptable or not?Absolutely YesQ3:What's kind of Payment terms for customer choosing?T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...Q4:Can we visit your factory online?Absolutely no problemQ5:Can online video inspection before shipment?Absolutely no problemQ6: what's the MOQ ? Sample order is OK?MOQ:1 set, sample order is no problemQ7:What's kind of shipment for customer choosing?Usually ship by sea, by air, by international express .We can also provide reasonable solutions according to your transportation requirementsQ8:How to ensure product quality and after-sales service?We have CE, ISO quality certificate, and SGS authentication.After-sale service:Warranty : 1 yearWe supply free part for quality problem in warrantyLong life technical support and service
Type: Balancing Machine
Warranty: 1 Year
Standard: ISO13320-1:1999, GB/T19077.1-2008, Q/Jwn001-2009
Principle: Mie Scattering Principle
Accuracy Error: <1% (National Standard Sample D50 )
Laser Diffraction Nano Measurement Tester Particle Size Analyze Analyzer Product Description CharacteristicsWork principle: The laser particle size analyzer is based on full measuring range of Mie scattering theory, sufficiently considering the optics nature such as sample and decentralized medium refraction coefficient and so on. On the basis of laser illuminate size and the size distribution regular pattern of scattering light energy that comes from the sample inversely calculate out sample group.Technique feature: The laser particle size analyzer work principle is well-developed, hardware design is very reasonable, the product is designed according to the international engineering standard ISO-13320, GMP Regulation and FDA/21CFR 11 absorbs England, America, Germany and other countries well-developed experience on the size analysis, all features of the product are domesticly and leading.Illuminant: The laser particle size analyzer adopts He-Ne's laser make illuminant, the wavelength is 0.6328 micron, wavelength is short, string breadth is narrow, stability is good, and laser power source and laser tube service life is more than 25000 hours.Light electricity probe: The laser particle size analyzer light electricity system is designed uniquely. The primary detector is one, many assist detectors presenting non-uniform intercourse and three dimension fan-shaped ranges matrix rank. The largest test examination horn angle attainability is up to 135°Light route: The laser particle size analyzer adopts a measuring range designed, the convergent light route is unique, decreasing Fourier lens, as a result the measurement range broader, the resolution is higher, the error is minimal.Specifications Dispersion methodSpecificationsDimensionsWeight(Net)CY-2002Wet1,measurement range:0.1-800μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)1000×330×320mm38kgCY-2006Wet1,Measurement range:0.05-1200μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2008Wet1,Measurement range:0.02-2000μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2009Wet1,Measurement range:0.02-2600μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50) CY-2012Dry 1,Measurement range:0.1-800μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)Main system: 1000×330×320mmDry sampling system:350×330×300mm40kgCY-2016Dry1,Measurement range:0.1-1200μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2018Dry1,Measurement range:0.1-2000μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2019Dry1,Measurement range:0.1-2600μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2022Wet/Dry1,Measurement range:0.1-800μm/2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)Main system: 1000×330×320mmDry sampling system:350×330×300mmWet sampling system:350×330×300mm 50kgCY-2026Wet/Dry1,Measurement range:0.05-1200μm(wet)0.1-1200μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2028Wet/Dry1,Measurement range:0.02-2000μm(wet)0.1-2000μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2030Wet/Dry2,Measurement range:0.02-2600μm(wet)0.1-2600μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50) User-Friendly Operation:The operation is standard, quantized and simple .And it takes short time to master it. The data are tested within 1 minute. High Viewability:The test software is user-friendly. The test processes are readable and instantly refresh. The operators observe at any time the instrument's situation and the changes of the test data, and analysis reality and reliability of the test data. In the intelligent touch panel, there are operating keys for circulation, ultrasonic, stir and discharge. Due to the standard, quantized and simple operation, the test time is shortened and the requirement for the operators are lowered.Applied Range All kinds of metal powder: aluminite powder, zircon powder, nickel powder, tungsten powder, tin powder, zinc powder, molybdenum powder, magnesium powder, copper powder, rare metal powder, alloy powder, metallic oxide powder( exclusive of magnetic powder), etc.All kinds of nonmetal powder: talc powder, kaolin, calcium carbonate, , fluorescent powder, calcite, diamond, barite, fluorite, zeolite, boron carbide, clay, graphite, quartz, gypsum, bentonite, kieselguhr, zirconium silicate, corundum, mica, titanium. Others: soil, dyestuff, brenstone, explosive, western medicine, Chinese medicine, agricultural pesticide, grinding material, coatings, food additive, catalytic agent, concrete, river silt, oil drop, air bubble, emulsion. Packaging & ShippingOur AdvantagesFAQ
Type: Balancing Machine
Warranty: 1 Year
Standard: ISO13320-1:1999, GB/T19077.1-2008, Q/Jwn001-2009
Principle: Mie Scattering Principle
Accuracy Error: <1% (National Standard Sample D50 )
Price Laser Granulometer Particle Size Measurement Analyze AnalyzerProduct Description CharacteristicsWork principle: The laser particle size analyzer is based on full measuring range of Mie scattering theory, sufficiently considering the optics nature such as sample and decentralized medium refraction coefficient and so on. On the basis of laser illuminate size and the size distribution regular pattern of scattering light energy that comes from the sample inversely calculate out sample group.Technique feature: The laser particle size analyzer work principle is well-developed, hardware design is very reasonable, the product is designed according to the international engineering standard ISO-13320, GMP Regulation and FDA/21CFR 11 absorbs England, America, Germany and other countries well-developed experience on the size analysis, all features of the product are domesticly and leading.Illuminant: The laser particle size analyzer adopts He-Ne's laser make illuminant, the wavelength is 0.6328 micron, wavelength is short, string breadth is narrow, stability is good, and laser power source and laser tube service life is more than 25000 hours.Light electricity probe: The laser particle size analyzer light electricity system is designed uniquely. The primary detector is one, many assist detectors presenting non-uniform intercourse and three dimension fan-shaped ranges matrix rank. The largest test examination horn angle attainability is up to 135°Light route: The laser particle size analyzer adopts a measuring range designed, the convergent light route is unique, decreasing Fourier lens, as a result the measurement range broader, the resolution is higher, the error is minimal.Specifications Dispersion methodSpecificationsDimensionsWeight(Net)CY-2002Wet1,measurement range:0.1-800μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)1000×330×320mm38kgCY-2006Wet1,Measurement range:0.05-1200μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2008Wet1,Measurement range:0.02-2000μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2009Wet1,Measurement range:0.02-2600μm2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50) CY-2012Dry 1,Measurement range:0.1-800μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)Main system: 1000×330×320mmDry sampling system:350×330×300mm40kgCY-2016Dry1,Measurement range:0.1-1200μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2018Dry1,Measurement range:0.1-2000μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2019Dry1,Measurement range:0.1-2600μm 2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2022Wet/Dry1,Measurement range:0.1-800μm/2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)Main system: 1000×330×320mmDry sampling system:350×330×300mmWet sampling system:350×330×300mm 50kgCY-2026Wet/Dry1,Measurement range:0.05-1200μm(wet)0.1-1200μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2028Wet/Dry1,Measurement range:0.02-2000μm(wet)0.1-2000μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50)CY-2030Wet/Dry2,Measurement range:0.02-2600μm(wet)0.1-2600μm(dry)2,Error:<±1%(national standard materials D50)3,Repetitiveness deviation: <±1%(national standard materials D50) User-Friendly Operation:The operation is standard, quantized and simple .And it takes short time to master it. The data are tested within 1 minute. High Viewability:The test software is user-friendly. The test processes are readable and instantly refresh. The operators observe at any time the instrument's situation and the changes of the test data, and analysis reality and reliability of the test data. In the intelligent touch panel, there are operating keys for circulation, ultrasonic, stir and discharge. Due to the standard, quantized and simple operation, the test time is shortened and the requirement for the operators are lowered.Applied Range All kinds of metal powder: aluminite powder, zircon powder, nickel powder, tungsten powder, tin powder, zinc powder, molybdenum powder, magnesium powder, copper powder, rare metal powder, alloy powder, metallic oxide powder( exclusive of magnetic powder), etc.All kinds of nonmetal powder: talc powder, kaolin, calcium carbonate, , fluorescent powder, calcite, diamond, barite, fluorite, zeolite, boron carbide, clay, graphite, quartz, gypsum, bentonite, kieselguhr, zirconium silicate, corundum, mica, titanium. Others: soil, dyestuff, brenstone, explosive, western medicine, Chinese medicine, agricultural pesticide, grinding material, coatings, food additive, catalytic agent, concrete, river silt, oil drop, air bubble, emulsion. Packaging & ShippingOur AdvantagesFAQ