Ice Making: Immersing
Cooling Way: Evaporative Condenser
Automation: Automation
Unit Structure: Integral
Machine Size: Large
Specifications1,The leader of global concrete cooling system field;2,ASME for pressure vessels,CE certificate.3,Global after-sales serviceSnowman Concrete Cooling Systems consists of containerized ice machine, water chiller , automatic ice sorage bin, delivery system, weighing hopper.Features of the system (1) Small size, small area, convenient transportation(2) Rapid installation, adaptable to adverse surroundings(3) Fully automatic control, convenient operation and maintenance(4) easy and convenient to operate, and adaptable to adverse surroundings, works at the ambient temperature ranging from -30 .C to 56 .C.Advantages of flake iceFlake ice is flat in shape, which can be applied to seafood cooling, meat processing and industrial procedure. The most important use of SNOWKEY flake ice is concrete cooling, especially in hot climate. Though the flake ice is cooled down slightly-7, it is still a kind of dry ice, which means its heat quantity is potential and the main source of cooling energy can be 100% guaranteed. Since it is a kind of dry ice, the cooling input of flake ice can be calculated accurately and the temperature effect to the concrete mixture is obvious. Flake ice is movable freely. They will not stick together, and condense to lump. Therefore, flake ice is convenient to store and transport. Because of the above features and moderate production cost, flake ice is greatly applied to many industries and food processing. Carry-out standard1.White painted new container with air conditioner, illumination and aluminum door, meeting the International Organization for StandardizationISOrequirement 2.piston and screw compressor 3.motor IP55 insulation class F 4.1 set of evaporative condenser 5.1 set of ice maker with ice level control 6.automatic oil return system 7.water flow controller with ice maker indicator light 8.switch and control panel for automatic operation 9.stainless steel panel with stainless steel meters 10.assemble, pipeline and circuitry meet German standardSnowman Concrete Cooling Systems consists of containerized ice machine, water chiller , automatic ice sorage bin, delivery system, weighing hopper.Features of the system (1) Small size, small area, convenient transportation(2) Rapid installation, adaptable to adverse surroundings(3) Fully automatic control, convenient operation and maintenance(4) easy and convenient to operate, and adaptable to adverse surroundings, works at the ambient temperature ranging from -30 .C to 56 .C.Advantages of flake iceFlake ice is flat in shape, which can be applied to seafood cooling, meat processing and industrial procedure. The most important use of SNOWKEY flake ice is concrete cooling, especially in hot climate. Though the flake ice is cooled down slightly-7, it is still a kind of dry ice, which means its heat quantity is potential and the main source of cooling energy can be 100% guaranteed. Since it is a kind of dry ice, the cooling input of flake ice can be calculated accurately and the temperature effect to the concrete mixture is obvious. Flake ice is movable freely. They will not stick together, and condense to lump. Therefore, flake ice is convenient to store and transport. Because of the above features and moderate production cost, flake ice is greatly applied to many industries and food processing. Carry-out standard1.White painted new container with air conditioner, illumination and aluminum door, meeting the International Organization for StandardizationISOrequirement 2.piston and screw compressor 3.motor IP55 insulation class F 4.1set of evaporative condenser 5.1 set of ice maker with ice level control 6.automatic oil return system 7.water flow controller with ice maker indicator light 8.switch and control panel for automatic operation 9.stainless steel panel with stainless steel meters 10.assemble, pipeline and circuitry meet German standard1,Containerized Flake Ice Plant (from 10ton/day to 180ton/day);MODELFIP10FIP15FIP20FIP25FIP30FIP35FIP40FIP45FIP50FIP60FIP70FIP80FIP90FIP100FIP120FIP140FIP180ice capacity10t/day15t/day20t/day25t/day30t/day35t/day40t/day45t/day50t/day60t/day70t/day80t/day90t/day100t/day120t/day140t/day180t/daywater supply0.4t/hr0.6t/hr0.8t/hr1.1t/hr1.3t/hr1.5t/hr1.7t/hr1.9t/hr2.1t/hr2.5t/hr2.9t/hr3.4t/hr3.8t/hr4.2t/hr 5.1t/hr5.9t/hr 7.6t/hrnecessary cooling capacity65kw75kw100kw125kw150kw175kw200kw225kw250kw300kw350kw400kw450kw500kw600kw700kw900kwinstall power75kw81kw 88.9kw 115.8kw 145.8kw 136.4kw 174.2kw 209.4kw 222.1kw 222.1kw 256.9kw 334.5kw 388.8kw 440.1kw 440.1kw 509.7kw 771.7kw running powr59.8kw65.8kw76.6kw95.5kw 110.5kw 128.5kw 147.4kw 175.8kw 194.2kw 217.4kw 241.8kw 281.3kw 322.4kw 382.2kw 428.7kw 477.5kw 636.9kw water consume210L/hr226.9L/hr277.3L/hr347.3L/hr395.1L/hr 480.7L/hr 528.5L/hr 601.5L/hr 666.1L/hr 776.7L/hr 882.1L/hr 1021L/hr 1123L/hr 1333L/hr 1554L/hr1765L/hr 2248L/hr container20'20' 20' 40'40'40'40'40'40'40'40'2*40'40' 2,Containerized Ice Storage Bin(from 18ton/day to 200ton/day);MODELICE CAPACITY(Tons)TYPELENGTH(mm)WIDTHHEIGHTWEIGHAIS1818Container ized12192243825913.6AIS2323Container ized 12192243828964.5AIS40H40Container ized 121922438551512AIS4040Combined type121923530352015AIS5050Combined type121924130352015.5AIS50H50Combined type121923560400015.5AIS6060Combined type121924130400016AIS7575Combined type121925191400018AIS9090Combined type150005191400022.5AIS100100Combined type150005191431223AIS150150Combined type150005191587230AIS200200Combined type150005191743240 3,Containerized Water Chiller System(from 18ton/day to 200ton/day);MODELICW36ICW60ICW72ICW96ICW120ICW156ICW180ICW240ICW312ICW360ICW480ICW576cold water capacity(Tons/day)36607296120156180240312360480576necessary cooling capacity(kw)66.5110.8133177.3221.7288.2332.5443.3576.3665886.81064power consume(kw)18.927.337.846.453.976.182.2111154.8157.9214.3271.1COP(kw/kw)3.84.33.744.344.24.23.94.44.44.1container size20'20'20'20'20'20'20'40'40'40'40'40'(advise)water tank volume(m³)1220243240526080104120160192
Type: Packaged Rooftop Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Low
Adaptable, Flexible Rooftop Solutions For Virtually Any Building HYC rooftop units offer superior indoor air quality, industry leading energy efficiency, hassle-free installation-everything you need for new construction or replacement projects.Inverter Rooftop Packaged Air Conditioning Unit Inverter rooftop packaged unit refers to the inverrter compressor.The most common types of compressors are the fixed speed compressor. The fixed speed will run at 100% of its capacity and will stop and start automatically to maintain the desired temperature. An inverter compressor will vary its speed in order to maintain a consistent temperature. They convert the AC power into DC to all the control of the outdoor unit compressor speed.This gives the unit better accuracy to provide a constant temperature and less energy wastage. Comparison with non-frequency conversion rooftop packaged unit:More comfortableWith a wider range of temperatures modes for heating and cooling,the inverter is able to operate in even the most extreme outdoor temperatures.An inverter compressor can also operate faster than non-inverter air conditioners thus allowing the air conditioners to reach the set temperature faster and bring you comfort sooner.More ComfortableWhen the air conditioner is initially activated to either heat or cool,the compressor will operate at maximum speed to reach the desired temperature is achieved,unlike non-inverter air conditioners that turn the compressor on and off,inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised.More Energy-efficientCompressor and motor speed in non-inverter type air conditioners remains constant and temperature is adjusted by turning the compressor and more ON and OFF,which consumes more energy.In inverter type air conditioners,temperature is adjusted by changing compressor frequency/motor speed without turning them ON and OFF.Therefor,the power loss of the inverter air conditioner is smaller,with can increase energy efficiency by about 35%.More EconomicsAll inverter systems are engineered and manufactured,ensuring performance.reliability,and efficiency.The increased efficiency and operation of our inverter systems reduce the wear tear on the compressor,contributing to durability and longevity of the system.FEATURESCOOLING CAPACITYCapacity ranging from 3Ton to 70Ton (8kW to 240kW)Cooling performance: -5~50ºCHeating performance: -20~24ºCINTEGRAL DESIGN AND EASY INSTALLATIONThe package rooftop has a integral design. It is supplied as a complete package ready for operation, with no extra controls or other items to be installed. The units have a single power point entry with simple connections.Quick start-up is assured once installation is completed, as each rooftop unit is manufactured in an ISO9001:2000 listed facility to guarantee quality. All units are tested at the factory to provide reliable start up.HIGHLY QUALITY COMPONENTS AND RELIABLE PERFORMANCEDC inverter type compressor and high quality world known brand cooling parts, which ensures units' reliable performance.STANDARD FEATURES• Easily accessible system components• Factory micro-programmed LED controller.• Heavy duty mounting chassis for the whole unit with lifting holes• BMS• Anti-vibration mounting compressor and centrifugal fan• Weather-proof, polyester epoxy powder electrostatic paint oven-baked finish for sheet metal and base frame• Compressor, fan motor inner protect• Treated anti-corrosion protection for coils (blue fins) for copper/aluminum coils condensor and evaporatorOPTIONAL• Inverter type condensing fan• Inverter type evaporating fan• Optional supply/return air configurations, optional bottom supply and return type.• Copper fin condensor and evporator for some area need special anti-corrision• Blygold paintting for condensor and evporator for some area need special anti-corrision• Stainless steel body cover and drain pan• Economizer with fresh, return air dampers and fresh air hood• Control device for operation of outdoor units at low ambient temperaturesModel 003004005006007008010012Nominal cooling capacitykW10.114.2 17.4 20.224.429.234.841.2Nominal heating capacitykW10.415.0 18.020.824.830.436.042.5Rated power inputkW3.495.11 5.83 7.23 8.35 10.33 12.2713.52Power supply/380~415V / 3Ph / 50HzCompressorQuantityNr.11122222Input powerkW2.69 4.04 4.66 5.386.58.089.3210.58Input currentAmps5.00 7.11 8.33 1012.3814.2216.6620.18Type/ScrollEvaporator sectionFan quantityNr.1 1 1 1 1 1 11Air flowm3/h1900 2800 3140 4150 4500 5500 69007500Fan type/Centrifugal fanDrive type/Direct drive (belt drive optional)ESPPa150 150 180 150 180 180 200200Condensor sectionFan quantity/1 1 1 1 1 1 22Fan type/Axial fanUnit dimensionLengthmm1340 1583 1583 192119212073 23002533Widthmm991 991991 1397 1397 1469 16261826Heightmm880 880 880 10781078 1001 11021167Net weightkg200 210 220 340 360 380 700750Sound pressure levelsdB(A)65 65 65 65 67 68 6868Model 015020025030035040045055 070Nominal cooling capacitykW52.471.086.097.0124.0140.4158.0188.0 240.0Nominal heating capacitykW53.273.087.098.2128.0144.0162.0192.0248.0Rated power inputkW19.04 25.2630.434.545.850.5255.470.486.2Power supply/380~415V / 3Ph / 50HzCompressorQuantityNr.222244444Input powerkW13.7418.2620.724.732.2436.5241.449.465.4Input currentAmps25.832.5638.0449.859.2865.1676.0899.6110.96Type/ScrollEvaporator sectionFan quantityNr.1 1 1 1 1 11 1 1Air flowm3/h10000 14000 15000 16000 23200 2600029500 32000 47000Fan type/Centrifugal fanDrive type/Belt drive (direct drive optional)ESPPa220 250 250 250320 320360 360 420Condensor sectionFan quantity/2 2 2 244444Fan type/Axial fanUnit dimensionLengthmm2533 3400 3684 3790 5100580058005800 5800Widthmm1820 2200 2200 2220 2239223922392255 2235Heightmm141715901590 1614 1668 17281728 2028 2028Net weightkg840 1240 1300 1356 1720 19002000 2200 2300Sound pressure levelsdB(A)69 70 70 7078 78818184Qingdao Hongyu Cles Air Conditioning Co., Ltd.Hongyu cles air conditioning(HYC) are dedicated to providing market leading innovations and new technologies that are easy-to-use solutions with the goal to always offer our client reduced energy outlay whilst empowering complete control to customize the solution for their business.Rooftop packaged unit production line Production machineryTest lab Sincerely welcome to visit our factory at your convience. Customer could witness their order production real conditions by online videos or photos at any time during production.
After-sales Service: Online and Offline
Warranty: 1 Year
Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: Aluminum-Zinc Plate
Product DescriptionClosed counter flow cooling towers are one of the methods of heat transfers. They are hybrids that pass the working fluid through a tube bundle, upon which clean water is sprayed and a fan-induced draft applied. The resulting heat transfer performance is much closer to that of a wet cooling tower, with the advantage provided by a dry cooler of protecting the working fluid from environmental exposure and contamination.Closed counter flow cooling towers operate similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid to the ambient air through a heat exchange coil. This creates two separate fluid circuits an external circuit, in which spray water circulates over the coil and mixes with the outside air, and an internal circuit, in which the process fluid circulates inside the coil. The coil isolate the process fluid from the outside air, keeping it clean and contamination free. Heat is transferred from the internal circuit, through the coil to the spray water, and then to the atmosphere as a portion of the water evaporates.Advantage:A. Because the closed cooling tower is totally closed circulating cooling, there is no debris entering the cooling pipeline system, resulting in pipeline blockage;B. Soft water circulation cooling, at high temperature, there is no scale formation, causing the cooling pipeline system scaling;C. The utility model has the advantages of small floor area, no need to dig a pool, convenient location, water saving and energy consumption reduction;D. The double cooling mode of air cooling, evaporation and heat absorption is adopted, which has high cooling efficiency;E. It can directly cool water, oil, alcohol, quenching liquid, salt water, chemical liquid and other media with no loss and stable composition;F. Due to the closed cycle, the medium is not affected by the environment and will not pollute the environment;G. The pressure loss of cooling water is smaller than that of open cooling tower.Detailed Photos Product ParametersDeliver Our CompanyAOSUA is professional experts of producing cooling tower's professional equipment, manufacturer and supplier of low noise cooling tower's special motor, motor redurcer, fan blade, water pump and so on. AOSUA has strong technical force, advanced production equipment, completed detectionmeans and so on. Aosua is complete in specifications,products widely used in hotels, metallurgy, chemical industry, steel industry and so on.Products of AOSUA had been used in many major project in our country with ideal curative effect. AOSUA builds on reputation,quality,price to expand the business,our pre-sale,on-purchase and after-sales service is first class.Professional:AOSUA produce cooling tower and cooling tower parts. We used to produce cooling tower power system parts like cooling tower fan, cooling tower motor reducer.AOSUA got ISO9001:2008 AOSUA is member of the CTI and the Chinese Association of Refrigeration. CertificationsPurchase NotesFAQQ1: Are you a factory or trading company? A: We are a professional cooling tower manufacturing factory, we have our own brand AOSUA.Q2: How does your factory do regarding quality control?A: Quality is priority.Q3:How about the packing of this product?A: We packed it in iron frame.Q4:Where is your loading port?A:Ningbo and shanghai port,China