AC Contactors with All Kinds of Voltage

Electricity Type: AC

Number of Pole: 3

Phase: 1

Main Circuit Rating Voltage: 380V

Main Circuit Rating Current: 9-95A

1.Application:JLC1-D series 660V 9-95A AC Contactor is applicable at the line of AC 50/60 Hz, rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reve-rsible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air timedelay head, mechanical interlock mechanism, etc. Moreover, it could act as the electromagnetic starter by the direct plug of the thermal relay.This product conforms to the requirement of IEC60947-4-1& GB14048.4 standards.2.Main parameterTypeRatedinsulationvoltage(V)Conventionalthermalcurrent(A)Ratedoperationcurrent(A)Control power(kw)No .ofcontactsRemark220V380V415V440V660VJLC1-09100901 6602092.24445.53P+NO3P+NC Installationmethod1.with twoscrews2.35mmdin railJLC1-12001201 201235.55.55.57.53P+NO3P+NC JLC1-18101801 321847.59993P+NO3P+NC JLC1-25102501 40255.5111111153P+NO3P+NC JLC1-32103201 50327.515151518.53P+NO3P+NC JLC1-401160401118.52222303P+NO+NCInstallationmethod1.with threescrews2.75mm or35mmdin railJLC1-501180501522253033JLC1-6511806518.530373737JLC1-8011125802237454545JLC1-9511125952545454545TypeJLC1-09JLC1-12JLC1-18JLC1-25JLC1-32JLC1-40JLC1-50JLC1-65JLC1-80JLC1-95Pick-up voltage50/60Hz(V)(0.85~1.1)Us(0.85~1.1) Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)UsRelease voltage50/60Hz(v)(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)UsCoil power50Hz60Hz Pick-up(VA)7070110110110200200200200200Holding(VA)881111112020202020Pick-up(VA)8080115115115200200200200200Holding(VA)881111112020202020Powerconsumption(W)1.8~2.71.8~2.73~43~43~46~106~106~106~106~103.We commit:4.shipping:

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 Contacts

Electricity Type: AC

Number of Pole: 3

Phase: 3

Type: Ac Contactors

Rated Current: 12A

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 ContactsProduct DescriptionCJX2s series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.Standard: IEC 60947-1, IEC 60947-4-1TypeAmaxBmaxCmaxabcdefCJX2s-09, 12, 1874.545.585.53550/60----CJX2s-25, 32, 388356.5974050/70----CJX2s-40, 50, 65127.574.5117--10540100/11059CJX2s-80, 95127.585.5125.5--10540100/11067 Company Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

AC Contactors with All Kinds of Voltage

Electricity Type: AC

Number of Pole: 3

Phase: 1

Main Circuit Rating Voltage: 380V

Main Circuit Rating Current: 9-95A

1.Application:JLC1-D series 660V 9-95A AC Contactor is applicable at the line of AC 50/60 Hz, rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reve-rsible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air timedelay head, mechanical interlock mechanism, etc. Moreover, it could act as the electromagnetic starter by the direct plug of the thermal relay.This product conforms to the requirement of IEC60947-4-1& GB14048.4 standards.2.Main parameterTypeRatedinsulationvoltage(V)Conventionalthermalcurrent(A)Ratedoperationcurrent(A)Control power(kw)No .ofcontactsRemark220V380V415V440V660VJLC1-09100901 6602092.24445.53P+NO3P+NC Installationmethod1.with twoscrews2.35mmdin railJLC1-12001201 201235.55.55.57.53P+NO3P+NC JLC1-18101801 321847.59993P+NO3P+NC JLC1-25102501 40255.5111111153P+NO3P+NC JLC1-32103201 50327.515151518.53P+NO3P+NC JLC1-401160401118.52222303P+NO+NCInstallationmethod1.with threescrews2.75mm or35mmdin railJLC1-501180501522253033JLC1-6511806518.530373737JLC1-8011125802237454545JLC1-9511125952545454545TypeJLC1-09JLC1-12JLC1-18JLC1-25JLC1-32JLC1-40JLC1-50JLC1-65JLC1-80JLC1-95Pick-up voltage50/60Hz(V)(0.85~1.1)Us(0.85~1.1) Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)Us(0.85~1.1)UsRelease voltage50/60Hz(v)(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)Us(0.2~0.75)UsCoil power50Hz60Hz Pick-up(VA)7070110110110200200200200200Holding(VA)881111112020202020Pick-up(VA)8080115115115200200200200200Holding(VA)881111112020202020Powerconsumption(W)1.8~2.71.8~2.73~43~43~46~106~106~106~106~103.We commit:4.shipping:

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

Geya Gyhc-25 DC Contactor for Hotel and Home Use Home AC Contactor and Mini Modular with AC 220V Home Contactor

Shipping Cost Estimated freight per unit.: To be negotiated

Electricity Type: DC

Number of Pole: 2

Phase: 1

Samples: US$ 12/Piece 1 Piece(Min.Order) | Order Sample

Product DescriptionLow power consumption:The GYHCseries modular contactor optimizes the electromagnetic system, greatly reducing the holding power of the contactor, and completely solves the problem of high energy consumption of traditional contactors.Low noise:GYHC series modular contactor adopts a new design to improve product reliability.60% of the production process is automated, and key processes throughout the process are monitored automatically. Eliminate the noise problems encountered in the operation of traditional contactors from the design and manufacturing process.Super long life:Electrical life greater than 100,000 times Mechanical life is more than 12,000,000 times TypeRated current(In)Control voltage (V) ContactMultiple Of The Width Of The Module (Multiple of 9 mm)AC-7aAC-7b1P16A6AAC 50/60Hz24V/48V/110V/230VDC:12V/24V1NO1NC220A7A25A9A2P16A6A2NO2NC1NO1NC220A7A25A9A32A12A440A15A63A20A3P16A6A3NO3NC420A7A25A9A32A12A640A15A63A20A4P16A6A4NO4NC2NO2NC3NO1NC420A7A25A9A32A12A640A15A63A20ACompany Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

Geya Gyhc-25 DC Contactor for Hotel and Home Use Home AC Contactor and Mini Modular with AC 220V Home Contactor

Shipping Cost Estimated freight per unit.: To be negotiated

Electricity Type: DC

Number of Pole: 2

Phase: 1

Samples: US$ 12/Piece 1 Piece(Min.Order) | Order Sample

Product DescriptionLow power consumption:The GYHCseries modular contactor optimizes the electromagnetic system, greatly reducing the holding power of the contactor, and completely solves the problem of high energy consumption of traditional contactors.Low noise:GYHC series modular contactor adopts a new design to improve product reliability.60% of the production process is automated, and key processes throughout the process are monitored automatically. Eliminate the noise problems encountered in the operation of traditional contactors from the design and manufacturing process.Super long life:Electrical life greater than 100,000 times Mechanical life is more than 12,000,000 times TypeRated current(In)Control voltage (V) ContactMultiple Of The Width Of The Module (Multiple of 9 mm)AC-7aAC-7b1P16A6AAC 50/60Hz24V/48V/110V/230VDC:12V/24V1NO1NC220A7A25A9A2P16A6A2NO2NC1NO1NC220A7A25A9A32A12A440A15A63A20A3P16A6A3NO3NC420A7A25A9A32A12A640A15A63A20A4P16A6A4NO4NC2NO2NC3NO1NC420A7A25A9A32A12A640A15A63A20ACompany Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 Contacts

Electricity Type: AC

Number of Pole: 3

Phase: 3

Type: Ac Contactors

Rated Current: 12A

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 ContactsProduct DescriptionCJX2s series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.Standard: IEC 60947-1, IEC 60947-4-1TypeAmaxBmaxCmaxabcdefCJX2s-09, 12, 1874.545.585.53550/60----CJX2s-25, 32, 388356.5974050/70----CJX2s-40, 50, 65127.574.5117--10540100/11059CJX2s-80, 95127.585.5125.5--10540100/11067 Company Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

Geya Gyhc-25 DC Contactor for Hotel and Home Use Home AC Contactor and Mini Modular with AC 220V Home Contactor

Shipping Cost Estimated freight per unit.: To be negotiated

Electricity Type: DC

Number of Pole: 2

Phase: 1

Samples: US$ 12/Piece 1 Piece(Min.Order) | Order Sample

Product DescriptionLow power consumption:The GYHCseries modular contactor optimizes the electromagnetic system, greatly reducing the holding power of the contactor, and completely solves the problem of high energy consumption of traditional contactors.Low noise:GYHC series modular contactor adopts a new design to improve product reliability.60% of the production process is automated, and key processes throughout the process are monitored automatically. Eliminate the noise problems encountered in the operation of traditional contactors from the design and manufacturing process.Super long life:Electrical life greater than 100,000 times Mechanical life is more than 12,000,000 times TypeRated current(In)Control voltage (V) ContactMultiple Of The Width Of The Module (Multiple of 9 mm)AC-7aAC-7b1P16A6AAC 50/60Hz24V/48V/110V/230VDC:12V/24V1NO1NC220A7A25A9A2P16A6A2NO2NC1NO1NC220A7A25A9A32A12A440A15A63A20A3P16A6A3NO3NC420A7A25A9A32A12A640A15A63A20A4P16A6A4NO4NC2NO2NC3NO1NC420A7A25A9A32A12A640A15A63A20ACompany Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 Contacts

Electricity Type: AC

Number of Pole: 3

Phase: 3

Type: Ac Contactors

Rated Current: 12A

CNC Cjx2s 220V, 110V, 380V, 415V 50/60Hz AC Magnetic Contactor with 2 ContactsProduct DescriptionCJX2s series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.Standard: IEC 60947-1, IEC 60947-4-1TypeAmaxBmaxCmaxabcdefCJX2s-09, 12, 1874.545.585.53550/60----CJX2s-25, 32, 388356.5974050/70----CJX2s-40, 50, 65127.574.5117--10540100/11059CJX2s-80, 95127.585.5125.5--10540100/11067 Company Profile

Besi Buy

Diamond Member

Audited Supplier

广东省 ,China